+92 21 3889 7650 info@solidcoretech.pk Mon–Sat: 09:00 AM – 06:00 PM
SECP-Registered Serving Karachi · Lahore · Islamabad · Faisalabad Request Free Site Survey
[ INFRASTRUCTURE INTEGRATOR ] PAKISTAN-WIDE FIELD TEAMS SECP REGISTERED

We Design, Build & Maintain Critical Infrastructure for Data Centers and Enterprise Facilities.

From server room infrastructure and structured cabling to CCTV, access control, fire detection, and power systems, SolidCore Technologies brings essential infrastructure services together through a coordinated project approach.

Integrated Infrastructure Scope
Engineered to TIA-942 / NFPA Standards
Full Handover Dossier & Test Certs
Written Response SLAs on AMC

Multiple Disciplines

One accountable project contract covering DC whitespace, power, cabling, CCTV & fire safety.

Technical Assessment

No guesswork. On-site engineering risk audit followed by an itemized, transparent BOQ in 5 days.

Witnessed Commissioning

Full handover dossier: as-built drawings, Fluke test certs, panel soak test logs, and O&M manuals.

Planned Maintenance

Scheduled preventive maintenance visits with contractually agreed, written response times (≤4h available).

Coordinated Technical Services Under One Roof

Rather than coordinating five separate subcontracting vendors who point fingers when systems fail, SolidCore integrates power, cabling, electronic security, and life safety into a unified delivery model.

Data Center & Server Rooms

Server room layout, containment, raised flooring, environmental sensors, and rack power infrastructure.

  • Server rack layout & airflow planning
  • Anti-static raised flooring & cable trays
  • DC environmental & temp monitoring
Explore Service

Structured Cabling & Fiber

End-to-end Cat6/Cat6A copper backbones, OM3/OM4 optical fiber splicing, patch panels, and TIA-606 labeling.

  • Certified Cat6 / Cat6A installations
  • Optical fiber fusion splicing & OTDR tests
  • 100% Fluke DSX certification reports
Explore Service

CCTV & Access Control

High-definition IP surveillance, NVR/VMS storage calculation, biometric access doors, and turnstiles.

  • Angle-of-view & storage design
  • RFID & biometric door access controllers
  • VLAN network isolation & hardening
Explore Service

Fire Detection & Alarms

Intelligent addressable fire alarm panels, optical smoke sensors, sounder strobes, and Civil Defence NOC compliance.

  • Addressable loop panels (EN 54 / NFPA 72)
  • High-sensitivity smoke detection (VESDA)
  • HVAC trip & sounder integration
Explore Service

UPS & Power Distribution

Online double-conversion UPS systems, load profiling, battery string audits, and isolated power distribution boards.

  • 1 kVA to 200+ kVA load rightsizing
  • Rack PDUs & ATS automatic transfer
  • Multi-brand UPS battery health testing
Explore Service

ELV & Integrated Systems

Public address & voice alarm (PA/VA), IP intercoms, video door entry, and coordinated building-level cabling dossiers.

  • Single unified ELV design schematic
  • Zone-based emergency PA/VA broadcasts
  • Video intercom & visitor verification
Explore Service
Delivered via Qualified Partner

Clean-Agent Fire Suppression

NFPA 2001 clean-agent gas flooding (FM-200 / Novec 1230), room-integrity testing, and server room nozzles.

  • Agent quantity hydraulic calculations
  • Door-fan room integrity pressure testing
  • Safe non-conductive residue-free discharge
Explore Service

Maintenance & AMC Plans

SLA-backed maintenance contracts with written response time commitments, health audits, and multi-brand coverage.

  • Written 4h / 8h / NBD response commitments
  • Scheduled quarterly or monthly visits
  • Third-party installation takeover audits
Explore Service

Multiple Systems. One Coordinated Project.

Save weeks of coordination hassle. We bundle physical infrastructure into coherent, pre-engineered solutions with guaranteed accountability and a single point of project contact.

For Commercial Buildings & Campuses

CCTV & Access Control Package

Solves Blind Spots & Tailgating: Engineered coverage design replaces unscientific camera counts. Guarantees storage compliance and biometric audit trails.
What's Included in Base Scope:
  • Comprehensive site survey & angle-of-view layout
  • HD/4K IP cameras with nighttime IR/WDR
  • NVR/VMS with RAID storage (30/60/90 days retention)
  • RFID / Fingerprint / Facial access controllers
  • Dedicated PoE switching & VLAN cybersecurity
  • Operator console setup & administrative training
For Banks, IT Facilities & Archives

Fire Protection for Server Rooms

Solves Catastrophic Hardware Loss: Water sprinklers destroy servers; manual extinguishers are too late. We deliver automated detection and gas suppression.
What's Included in Base Scope:
  • NFPA 72 compliant addressable detection panel
  • Dual cross-zoned optical smoke sensors
  • Clean-agent suppression cylinder (FM-200 / Novec)
  • Calibrated discharge nozzles & abort switch
  • Room integrity fan pressure test (Pass certificate)
  • Civil Defence / Rescue 1122 documentation pack

From Site Assessment to Documented Handover

Most contractors drop boxes and leave unlabelled wires. At SolidCore, we enforce a strict 6-stage delivery process backed by tangible documentation at every milestone.

01

Site Survey & Risk Audit

Physical inspection of room dimensions, power loads, containment routes, and security blind spots.

Output: Survey Assessment Sheet
02

Engineering & Itemized BOQ

System calculations (UPS sizing, camera retention, gas volume) and a transparent, itemized Bill of Quantities.

Output: Itemized Technical BOQ
03

Procurement & Planning

Genuine hardware sourced through authorized distributors with manufacturer serial numbers recorded.

Output: Material Submittal Dossier
04

Installation & Integration

Trained field engineers execute cabling to TIA-568, rack dressing to TIA-606, and fire alarm loop wiring.

Output: Physical Works Milestone
05

Testing & Commissioning

Witnessed Fluke certification, 72-hour panel soak test, sounder decibel checks, and camera focusing.

Output: Witnessed Sign-off Sheet
06

Handover Dossier & AMC

Delivery of complete as-built CAD drawings, Fluke reports, user training, and activation of SLA maintenance.

Output: Full Handover Dossier
Read Complete Delivery Methodology

Built for Facilities Where Downtime Is Not an Option

We understand the specific regulatory, audit, and operational constraints faced by professional facility and IT managers across Pakistan.

Banking & Financial Services

State Bank of Pakistan (SBP) compliance, branch CCTV retention standards, branch UPS runtime, and safe fire suppression.

Banking Solutions

Data Centers & IT Facilities

Designed to ANSI/TIA-942 and NFPA 75 recommendations. Clean power distribution, hot/cold aisle isolation, and environmental alarms.

Data Center Solutions

Commercial & Corporate Campuses

Unified ELV networks, speed gates, visitor badges, emergency voice alarm (PA/VA), and structured office Cat6A cabling.

Commercial Solutions

Industrial & Manufacturing

Harsh-environment optical fiber links, perimeter CCTV with intelligent analytics, industrial fire NOC certification readiness.

Industrial Solutions

Maintenance With Clear Scope & Written Response Commitments

Most vendors promise "24/7 support" and disappear when an alarm trips. We publish transparent, contractually enforceable response SLAs backed by scheduled preventive health visits.

Service Attribute
Essential
Small Offices & Retail Branches
Recommended
Professional
Corporate Campuses & Server Rooms
Enterprise
Data Centers & Bank Hubs
Scheduled Preventive Visits 4 Visits / Year (Quarterly) 12 Visits / Year (Monthly)
Emergency Response SLA Next Business Day ≤ 2 Hours (Urban Hubs)
Systems Covered CCTV + Access Control or UPS Full Physical Stack (DC, Power, Fire, ELV)
Battery & Power Audits Voltage check per quarter Full cell conductance & discharge soak log
Spares Priority Standard availability Guaranteed on-shelf spare stock
Documentation Output Checklist sign-off Monthly Executive Audit Dossier
Third-Party System Takeover Available after health audit Available with remediation plan
Next Step
Tier 1: Essential

Essential AMC

4 Preventive Visits/Year · Next Business Day Response

  • Quarterly physical & electrical checks
  • Lens cleaning & focus alignment
  • Fire panel detector test log
Tier 3: Enterprise

Enterprise AMC

12 Monthly Visits/Year · ≤ 2 Hours Response

  • 24/7 critical hotline access
  • Dedicated account lead engineer
  • Monthly compliance & health audit dossier

* Note: Third-party installed systems require an initial on-site physical health audit prior to formal AMC onboarding to identify pre-existing hardware faults.

Documented Work. Clear Scope. Verifiable Handover.

As a newly registered infrastructure firm, we do not show anonymous logos or invented statistics. We prove technical competence through the rigor of our engineering handover dossiers.

SOLIDCORE QA/QC FIELD INSPECTION PROTOCOL — SAMPLE EXTRACT STATUS: VERIFIED
[QC-UPS-01] Online UPS 72-Hour burn-in soak test completed under 80% resistive dummy load with zero alarms.
[QC-CCTV-02] Camera lux sensitivity and focal angle verified per design layout; night IR cut-filter transition logged.
[QC-FIRE-03] Loop address verification: each sensor smoke chamber tested with aerosol smoke; response time ≤ 3 sec.
[QC-FIRE-04] Sounder strobe decibel test: > 75 dBA recorded at bedhead/workstation locations per NFPA 72 §18.4.
[QC-ACC-05] Fail-safe electromagnetic lock release verified upon fire panel trip alarm trigger.
FLUKE NETWORKS DSX-8000 CABLEANALYZER™ REPORT FORMAT TEST STANDARD: TIA Cat 6A Channel
Length: 64.2m (Limit: 100m) | Propagation Delay: 312 ns | Delay Skew: 14 ns — PASS
NEXT (Near-End Crosstalk): Margin 6.8 dB @ 498 MHz (Worst Pair: 12-36) — PASS
Return Loss (RL): Margin 5.1 dB @ 250 MHz — PASS
Optical Fiber OTDR: OM4 50/125µm 850nm Attenuation ≤ 2.8 dB/km | Loss per fusion splice < 0.05 dB — PASS
AS-BUILT CAD DRAWING & TIA-606 LABELING SCHEME DRAWING REF: SC-DC-001-REV-C
Structured Identification: [Building-Floor-Rack-PatchPanel-Port] e.g. B1-02-RK01-PP02-P24 labeled at both ends.
CAD Single-Line Power Diagram (SLD) depicting UPS bypass, distribution busbars, and dual A+B power paths.
CCTV conduit and containment routing overlay showing actual pull box locations and cable tray capacities.
CLIENT OPERATIONS & MAINTENANCE (O&M) MANUAL TABLE OF CONTENTS VOL 1: SYSTEMS ADMINISTRATION
Section 1: Emergency Shutdown & Manual Bypass Procedures (UPS & Fire Suppression isolation).
Section 2: VMS Operator User Guide, Admin Credential Recovery, and Video Clip Export Protocol.
Section 3: Routine Preventive Maintenance Schedules (Daily/Monthly/Quarterly Operator Checklists).
Section 4: OEM Warranty Certificates, Serial Numbers Registry, and AMC Escalation Matrix.

Every SolidCore client receives this complete documentation binder in physical hardcopy and searchable PDF on project handover.

Explore Documentation Protocols

Technical Work Guided by Recognized Standards

We build strictly with reference to international engineering codes and Pakistani regulatory statutory requirements.

Clear Truth in Advertising Statement:

Referencing an international engineering standard describes the rigorous design principles and installation tolerances our engineers follow on your project. It does not imply that our corporate entity holds third-party ISO or Tier-III accreditation unless officially certified.

DATA CENTERS

ANSI/TIA-942 & NFPA 75

Guidelines for telecommunications infrastructure, hot/cold aisle architecture, redundancy classifications, and fire protection for IT equipment.

TELECOM & CABLING

TIA-568 & TIA-606

Commercial building telecommunications cabling standards and structured administration labeling schemes for copper and optical fiber.

LIFE SAFETY & NOC

NFPA 72 & EN 54

National Fire Alarm and Signalling Code and European harmonized standards for fire detection components demanded in Pakistani bank tenders.

Read Our Complete Technical Standards Guide

Technical Insights for Facility & IT Leaders

Unbiased engineering guides written to help procurement managers and IT directors evaluate equipment, standards, and vendor proposals.

Browse All Technical Guides

Frequently Asked Questions

Clear, honest answers to the practical questions facility directors and IT managers ask before engaging.

SolidCore directly executes structured cabling (Cat6/Cat6A & fiber), CCTV surveillance, access control, addressable fire alarm detection, online UPS sizing and installation, ELV coordination, and preventative AMC plans. For specialized clean-agent gas suppression (FM-200/Novec) and heavy civil works, we partner with verified, certified engineering specialists while managing the overall project under our single contract.

Yes. We offer complete supply-and-install turnkey solutions. We source genuine equipment through verified authorized distribution channels with manufacturer warranties and transparent, itemized Bills of Quantities (BOQ). Alternatively, if your organization already holds hardware stock, we can provide professional installation, testing, and commissioning services.

Yes. Many of our AMC clients come to us because their original installer disappeared or failed to deliver reliable support. We conduct an initial on-site physical health audit of your installed CCTV, fire alarm, or UPS hardware, document pre-existing defects, and onboard your installation under our SLA-backed maintenance contracts.

Our engineering site survey includes a physical inspection of your room layout, cable routes, power distribution capacity, fire risk assessment, and surveillance angles. Within 5 business days following the survey, we provide an engineered recommendation report with an itemized, transparent BOQ.

Every completed project is handed over with our formal Commissioning Dossier. This includes CAD as-built drawings, full Fluke copper and fiber test certification reports, panel soak test logs, equipment warranty cards, operation and maintenance manuals, and client operator training records.

Yes. While our primary engineering hub is in Karachi, we deploy mobile field engineering survey teams for projects in Lahore, Islamabad, Rawalpindi, and Faisalabad. We also support multi-site branch rollouts for financial and enterprise customers across Pakistan.

Response times are explicitly stated in writing in our AMC service contracts based on your selected tier (Essential: Next Business Day; Professional: ≤ 4–6 hours; Enterprise: ≤ 2 hours in major urban centers). All service calls are logged with timestamped dispatch records and resolution reports.

SCHEDULE YOUR TECHNICAL ASSESSMENT

Tell Us About Your Facility. Let's Plan the Right Infrastructure Solution.

Share your project scope, facility type, or maintenance pain points. A SolidCore technical coordinator will contact you within 24 hours to arrange an engineered on-site survey.

Contact Engineering Desk +92 21 3889 7650

Quick Site Survey Request

Field engineers available across Karachi, Lahore, and Islamabad/Rawalpindi.