CRITICAL POWER CONTINUITY

UPS & Clean Power Distribution Systems

Online double-conversion UPS systems, precision active load profiling, VRLA/Lithium battery string maintenance, intelligent rack PDUs, and clean isolated telecommunications grounding.

Eliminating Dirty Power and Unexpected Shutdowns

Pakistan's electrical grid is plagued by frequent voltage sags, harmonic distortion, transient spikes, and blackouts. In a server room or financial facility, these anomalies corrupt databases and degrade sensitive power supply units over time.

SolidCore delivers true online double-conversion power trains. We size UPS systems based on measured active load (kW) rather than deceptive kVA nameplate ratings, design isolated grounding busbars to eliminate neutral-earth float, and provide multi-brand maintenance takeover for existing installations.

Common Power Vulnerabilities We Resolve:

  • Single battery cell failure collapsing an entire 32-block UPS string
  • Neutral-to-earth voltage floating above 5V, frying server network interface cards
  • Undersized UPS tripping into bypass during utility power generator cutover
  • Inability to service or bypass the UPS without shutting down the entire server room

UPS Load & Redundancy Estimator

Estimate the recommended UPS kVA capacity and battery configuration for your IT environment:

e.g. 3 racks @ 5 kW each = 15 kW
Recommended UPS Rating
25 kVA (Standalone N)
Estimated Battery Strings
2 Battery Bank String(s) (12V VRLA)

* Sizing incorporates 25% future expansion headroom and 80% maximum operating load buffer.

What Our Power Scope Includes

Online Double-Conversion Systems (1 to 200+ kVA)

High-frequency, true sine-wave UPS systems with zero millisecond transfer time to batteries during outages.

External Maintenance Bypass Panels (EMB)

Wrap-around make-before-break manual bypass switches allowing the UPS to be serviced or replaced without dropping the load.

VRLA & Lithium Battery Health Testing

Individual cell internal resistance, open-circuit voltage, and discharge soak load testing to catch failing cells early.

Clean Telecommunications Earth Grounding

Low-impedance isolated grounding busbars engineered to achieve < 1 Ohm resistance to protect sensitive network hardware.

Tangible Deliverables You Receive on Handover

Single-Line Diagram (SLD)

CAD power schematic showing utility feed, bypass switch, UPS, and rack PDU circuit breakers.

72-Hour Burn-in Soak Log

Recorded temperature and electrical load logs under 80% dummy resistive load testing.

Battery Impedance Report

Baseline cell-by-cell milliohm resistance sheet used to track battery aging over AMC visits.

Have an Existing UPS Installed by Another Vendor?

You do not need to replace working equipment to get dependable maintenance. SolidCore provides multi-brand AMC support (APC/Schneider, Vertiv/Liebert, Riello, Eaton, and others) after an initial on-site physical health audit.

Explore AMC Takeover Options

Audit Your Critical Power & Battery Health

Request an on-site power load survey or UPS health audit with SolidCore engineers.