Clean-Agent Gas Fire Suppression Systems
NFPA 2001 total flooding gas fire suppression (FM-200 / HFC-227ea and Novec 1230 / FK-5-1-12) for server rooms, tape libraries, and critical electronics. Non-conductive, zero-residue protection delivered with our certified partner network.
Extinguish Fires Without Destroying Servers
Traditional water sprinklers or dry chemical ABC powder extinguishers will extinguish a flame — but they immediately corrode circuit boards, short-circuit motherboards, and destroy millions of rupees worth of enterprise computing infrastructure.
Clean agents extinguish fires at the molecular level within 10 seconds of discharge by absorbing heat. They leave zero particulate residue, conduct no electricity, and allow electronics to remain powered up without downtime during minor incidents.
Why Room Integrity Testing is Essential:
A clean agent system cannot extinguish a fire if gas leaks through unsealed cable penetrations or false ceiling gaps before reaching the required 10-minute hold time.
Every SolidCore suppression scope includes door-fan enclosure integrity pressure testing to certify room airtightness per NFPA 2001 §8.7.
What Our Clean-Agent Scope Includes
Precise volume, piping friction, nozzle orifice diameters, and agent weight calculation guaranteeing full discharge within 10 seconds.
Suppression only activates when two independent detector zones confirm smoke, preventing catastrophic accidental discharges.
Schedule 40 seamless piping and 360-degree radial dispersion nozzles engineered to prevent turbulence or rack displacement.
Physical fan pressurization test measuring room leakage area to guarantee the mandatory 10-minute gas retention concentration.
Tangible Deliverables You Receive on Handover
Official OEM software calculation showing agent density and discharge flow rates.
Pressure test report certifying enclosure airtightness meets NFPA 2001 retention limits.
Certified hydrostatic pressure test paperwork and tare weight calibration record.
FM-200 vs. Novec 1230
Need help deciding which clean agent fits your environmental policy and budget? Read our technical guide:
Protect Your Server Room With Clean Agent Suppression
Request a room volume audit and engineering estimate with SolidCore's fire safety specialists.